The era of data informatization has been developed in depth, and optical communication has rapidly extended to various fields. With the advent of the 5G era, 40G / 100G networks are widely used in data centers. The selection and installation of optical fiber connectors directly affect the information level of the entire data center. When choosing optical fiber connector, we may see the symbol of PC / APC / UPC. Do you know what PC / APC / UPC stands for?
PC Fiber Connector
PC fiber connector refers to the connector that is polished in the physical contact style. It is the most common polish type that is found on OM1 and OM2 multimode fiber. PC fiber connector was generated to overcome the air gap between two surfaces from small imperfections in the original flat fiber connector. In PC fiber connector design, there is a slightly cylindrical cone head with the aiming to eliminate the air gap, so that the typical return loss in single mode applications is about -40dB, higher than the return loss of the original flat polish style (-14 dB or roughly 4%). Up to now, this polish style has been outdated and the evolution - UPC polish style has come into being.
UPC Fiber Connector
UPC fiber connector is the acronym for Ultra Physical Contact. It is an improvement of the PC fiber connector with a better surface finish after an extended polishing and the return loss is better than PC structure, nearly -50dB or higher. Though it has a relatively lower back reflection in comparison with the PC connector, it is not robust enough. Note that repeated connections and disconnections will bring about the degradation of the surface and ultimate performance.
APC Fiber Connector
Out of the pursuit of lower back reflection, APC fiber connectors were developed. APC refers to Angled Physical Connect, the ferrule endface radius of which is polished at an 8°angel, minimizing the back reflection as a result. Since adding the angled endface, the reflected light will leak out into the cladding instead of staying in the fiber core. It should be noted that APC connectors should only be mated with other angled-polished connectors rather than non-angled polished connectors, or it will cause very high insertion loss. The optical return loss of APC connectors is -60dB or higher, better than the other connector types.
Appearance
The major difference in terms of appearance is the fiber endface. PC connectors and UPC connectors are both polished with no angle, though endface of UPC has a slight curvature. Instead, an APC connector is featured with 8° angle endface. Another obvious difference is the color. It is visible to distinguish which type of polish style the connector features by the color of the connector body. Take an FS LC APC single mode fiber optic patch cable as an example, the connectors on both fiber ends are all green. While for an LC UPC single mode fiber optic patch cable, the connectors are generally blue. It is also a simple way to tell these connectors apart.
Performance
It used to be hard to achieve low insertion loss using APC connectors owing to the air gap in the apex offsets, yet nowadays the improvement of connector design and manufacturing push APC connectors to perform better. The insertion difference between APC and UPC has been diminished. As for the performance of return loss, you may have noticed APC connectors have the lowest back reflection of all the fiber connectors mentioned owing to the angled endface. For this reason, the values of the return loss are different. According to the industry standards, the return loss of PC, UPC, and APC connectors is respectively about -40dB, -50dB, and -60dB or higher. The higher the return loss is, the lower the reflection and the better the connector performance will be. It proves that APC connectors are higher-performing among the connectors listed.
Application
Since some applications are more sensitive to return loss, APC connectors are preferred in these fields, for instance, in higher wavelength range like those used for RF video signals, especially FTTx applications and for applications such as passive optical networks and other WDM systems using high wavelength via single mode fiber. For those applications where return loss is not paid much attention to, UPC or PC comes into play. PC connectors are generally seen in telecom operators' equipment, while UPC connectors are popular in digital TV, telephony and data systems.
All in all, PC and UPC fiber connectors can be used on Ethernet equipment such as fiber switches. And they can be used with SFP optical modules. APC fiber connectors are mainly used for FTTX, passive optical network (PON) and wavelength division multiplexing (WDM). And it can not be used with SFP optical modules. The specific choice depends on the network needs.